Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/61456
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUniversidade Estadual de Campinaspt_BR
dc.typeArtigo de periódicopt_BR
dc.titleDetermination of the length of zygomatic implants through computed tomography: establishing a protocolpt_BR
dc.contributor.authorPena, Npt_BR
dc.contributor.authorCampos, PSFpt_BR
dc.contributor.authorde Almeida, SMpt_BR
dc.contributor.authorBoscolo, FNpt_BR
unicamp.author.emailnilsonpena@radiologia.odo.brpt_BR
unicamp.authorCampos, P. S. F. Univ Estadual Campinas, Piracicaba Dent Sch, Oral Radiol Postgrad Program, Sao Paulo, Brazilpt_BR
unicamp.authorde Almeida, S. M. Boscolo, F. N. Univ Estadual Campinas, Piracicaba Dent Sch, Dept Radiol, Sao Paulo, Brazilpt_BR
dc.subjectzygomapt_BR
dc.subjectdental implantationpt_BR
dc.subjecttomographypt_BR
dc.subjectX-ray computedpt_BR
dc.subject.wosAccuracypt_BR
dc.subject.wosMaxillapt_BR
dc.description.abstractObjectives: The aim or this study was to establish and verify ail examination protocol using CT to estimate the length of zygomatic implants, thus rendering the Surgical process safer and more predictable, and exposing the patient to a minimal level of radiation. Methods: Paracoronal CT scan was carried Out Oil ten dry human crania (n = 20) and the zygomatic implant sites were measured (L(CT)) bilaterally. A standard Surgical zygomatic implant placement procedure wits carried Out and the actual lengths and clinical lengths (L(Clin)) determined. Results: The averages of the L(CT), L(Clin) and L(Real) were 45.73 +/- 4.82 mm, 42.63 +/- 4.33 mm, and 44.73 +/- 4.53 mm, respectively. Student's t-test revealed no statistically significant differences between the L(Real) and L(CT) averages (P = 0.1532), whereas the L(Real) and L(Clin) averages were statistically different (P < 0.0001). Conclusions: The proposed protocol proved to be precise and efficacious ill the determination of zygomatic implant length, with the advantage to the patient of a relatively low level of exposure to radiation due to the small quantity of tomographic slices used. Although there were no major repercussions, the clinical probe in the zygomatic implant kit commonly used in this surgical procedure proved to be a rather imprecise tool.pt
dc.description.noteo TEXTO COMPLETO DESTE ARTIGO, ESTARÁ DISPONÍVEL À PARTIR DE AGOSTO DE 2015.pt
dc.relation.ispartofDentomaxillofacial Radiologypt_BR
dc.relation.ispartofabbreviationDentomaxillofac. Radiol.pt_BR
dc.publisher.cityLondonpt_BR
dc.publisher.countryInglaterrapt_BR
dc.publisherBritish Inst Radiologypt_BR
dc.date.issued2008pt_BR
dc.date.monthofcirculationDECpt_BR
dc.identifier.citationDentomaxillofacial Radiology. British Inst Radiology, v. 37, n. 8, n. 453, n. 457, 2008.pt_BR
dc.language.isoenpt_BR
dc.description.volume37pt_BR
dc.description.issuenumber8pt_BR
dc.description.firstpage453pt_BR
dc.description.lastpage457pt_BR
dc.rightsembargopt_BR
dc.sourceWeb of Sciencept_BR
dc.identifier.issn0250-832Xpt_BR
dc.identifier.wosidWOS:000261881900005pt_BR
dc.identifier.doi10.1259/dmfr/16676031pt_BR
dc.date.available2014-11-19T06:30:59Z
dc.date.available2015-11-26T17:03:19Z-
dc.date.accessioned2014-11-19T06:30:59Z
dc.date.accessioned2015-11-26T17:03:19Z-
dc.description.provenanceMade available in DSpace on 2014-11-19T06:30:59Z (GMT). No. of bitstreams: 1 WOS000261881900005.pdf: 390500 bytes, checksum: d1522c063b58b6d2b039e0b83c4c2b5e (MD5) Previous issue date: 2008en
dc.description.provenanceMade available in DSpace on 2015-11-26T17:03:19Z (GMT). No. of bitstreams: 2 WOS000261881900005.pdf: 390500 bytes, checksum: d1522c063b58b6d2b039e0b83c4c2b5e (MD5) WOS000261881900005.pdf.txt: 14937 bytes, checksum: 10270aadc780d8a9a09a01b5f76e35cc (MD5) Previous issue date: 2008en
dc.identifier.urihttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/61456pt_BR
dc.identifier.urihttp://www.repositorio.unicamp.br/handle/REPOSIP/61456
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/61456-
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000261881900005.pdf381.35 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.