Title: Neutron Time-of-flight Facility At The University Of São Paulo 8ud Pelletron Tandem Accelerator
Author: Wylie W.R.
Pessoa E.F.
Cybulska E.W.
Schelin H.R.
Fagundes L.M.
Nakayama K.
Douglas R.A.
Abstract: A fast neutron time-of-flight spectrometer designed for the 8UD Pelletron tandem accelerator is described. The characteristics of the Pelletron with regard to ion bunching are analyzed. The results of the first order klystron theory calculations are compared with data. Pulse shape discrimination, neutron detection and characteristic neutron time-of-flight spectra are shown. © 1979.
Citation: Nuclear Instruments And Methods. , v. 164, n. 2, p. 293 - 303, 1979.